Skip to main content
Loading…
This section is included in your selections.

The following design standards shall apply to the regional storm water facilities:

A. Whitewater River/Coachella Valley Storm Water Channel. Designed and constructed utilizing the SPS/SPF design standard. The 100-year-plus design standard will now be utilized for this facility, and for analyses addressing impacts associated with lands adjacent to this facility. The WWRSC/CVSC is owned, operated and maintained by CVWD.

B. Existing Tributary Regional Facilities (Owned, Operated or Maintained by CVWD Including USBR Protective Works, or Private Entity). Designed and constructed utilizing the SPS/SPF design standard. The 100-year-plus design standard will now be utilized for these facilities and for analyses addressing impacts associated with lands adjacent to these facilities. These existing tributary regional facilities can be owned, operated and maintained by CVWD or by a private entity that has an existing regional storm water facilities agreement with CVWD.

C. Existing Tributary Regional Facilities (Owned, Operated, or Maintained by Private Entity). Designed and constructed utilizing the 100-year storm/100-year flood design standard. The CVWD 100-year-plus design standard shall be utilized for changes to these facilities and for analyses addressing impacts associated with lands adjacent to these facilities. These facilities will continue to be owned, operated and maintained by a private entity.

D. Proposed Tributary Regional Storm Water Facilities. Design shall be based on the CVWD 100-year-plus design standard. CVWD shall assume operation and maintenance of proposed 100-year tributary regional storm water facilities. In the event a developer specifically requests to assume the operation and maintenance responsibility, CVWD shall determine, in its discretion, whether to approve such a request. In the event the request is approved, the requirements for private ownership, operation and maintenance of the proposed regional storm water facilities shall apply as set forth in CVWDC 3.20.060. (Ord. 1234.2 § 1, 2017)